DPH Series UPS, Three Phase, 25- 75/150/200 kW, Scalable Up to 800 kW in Parallel

The Modulon DPH Series UPS is a modular UPS used extensively for critical operations, since it provides 25% more power output compared to power factor 0.8 UPS systems. Designed for the most stringent datacenter requirements, the Modulon DPH Series offers the highest possible availability.

Introducing the Modulon DPH Series UPS – a next-gen modular solution designed for high availability, superior performance, and efficiency in medium-sized data centers. With a scalable architecture ranging from 25kW to 200kW (expandable to 800kW), it surpasses power factor 0.8 UPS systems, ensuring optimal power designs. The 19" enclosure allows versatile installation, and built-in redundancy, fault tolerance, and hot-swappable components guarantee uninterrupted power supply for mission-critical applications. Delta's Modulon DPH Series stands out with its top efficiency, making it the ideal choice for power protection and distribution in data centers.

Ultimate Availability

  1. Advanced fault tolerance design achieved by self redundancy guarantees operation continuity
  2. Self-synchronization of power and control modules for continuous on-line operation even in the event of control module failure avoids downtime caused by single point failure
  3. Hot-swappable key modules and components to ensure Mean Time To Repair (MTTR) close to zero without downtime risk

High Scalability

  1. Vertical expansion from 25 kW to 75/150/200 kW supporting N+X redundancy in a single rack enclosure reduces footprint
  2. Parallel expansion up to four units without requiring additional hardware
  3. Optional Rack-Mount Power Distribution Cabinet (rPDC) (applicable for 75/150 kW models) has flexibility to arrange its UPS’s output power feeding according to its connected critical loads
  4. Optional built-in battery modules (applicable for 75 kW models) at maximum four units (four battery trays each)

Excellent Power Performance and Efficiency

  1. Fully rated power (kVA=kW) maximizes power availability
  2. High AC-AC operating efficiency of 95% at 30% light load and 96% from 50% load results in marked energy cost savings
  3. Low harmonic pollution (iTHD < 3%) reduces upstream investment costs and meets demanding power requirements

Easy Maintenance

  1. Built-in manual bypass features eliminate maintenance-related downtime
  2. Proactive detection of fan failure and switch fault for early diagnosis of UPS malfunction
  3. Plug and play modularity simplifies the maintenance process